Mandates

Rogers

Rogers CNAM — TELUS

January 2007 – July 2007

Analysisimplementationtesting

Rogers CNAM had to deliver calling name to Rogers switches where TELUS is ILEC, and recover it for TELUS customers. Rogers used a different protocol than the TELUS network.

As translation prime I joined the national meetings, added translations, and built test plans with the Rogers analyst. I also found a GTD-5 compatibility issue affecting all Rogers–TELUS interactions in Canada, and applied the fix on the Quebec portion of the TELUS networks.

Impact

  • CNAM translations on targeted ILEC switches
  • Test plans built with the Rogers analyst
  • GTD-5 compatibility fix deployed in Quebec

Technologies

Nortel DMSGTD-5ExcelAccessReflection XPSP Guide
Download this mandate